Looking for help?
Find answers to your questions
-
X-trodes Support
- The LED of X-trodes device is showing a constantly blinking red light color. What should I do?
- What is the maximum range of the Bluetooth X-trodes device?
- How can I ensure good contact quality with the electrode?
- How to achieve high contact quality with EPOC Flex Gel
- How to select the Flex Cap size?
- How to quickly set up FLEX?
- Gel Solution for EPOC FLEX Gel
- How to clean EPOC FLEX Gel Sensors and Cap?
- How to clean EPOC FLEX Saline Sensors and Cap
- Quick Start Guide and User Manual
- Connecting to Service issue
- Where do I find EMOTIV Software to download?
-
EmotivPRO
- What is EEG Quality in the EmotivPRO?
- Does EmotivPRO automatically remove artifacts from the EEG data collected?
- How can timing markers be entered into the data stream?
- What do the values from the sensors mean?
- What Does EmotivPRO Software Include?
- How does BrainViz work?
- Is It Possible To Customize Frequency Bands In The 3D Brain Visualizer Application?
- What is an EEG Headset?
- Does EMOTIV offer EEG Headsets?
- How are EEG Headsets used for research?
- Are EMOTIV products medical devices?
- I received the hardware, how can I get access to Raw EEG data?
- What is included in the headset package?
- Can I wear EPOC+ or INSIGHT with VR headsets?
- What are the Performance Metrics Detection Suite?
- What are the detections based on? How were the algorithms created?
- Is EPOC+ or INSIGHT headset water resistant?
- What are the differences between EPOC+, Insight and Flex?
- Why do I need 9-axis inertial motion sensor?
- Why does the contact map show activity when the headset is not on my head?
- Does EMOTIV really measure signals from my brain?
- Can I use the headsets while charging?
- Is it safe to use EMOTIV products?
- Can EMOTIV headsets read Event-Related Potentials?
- What else can you say about EPOC+ or INSIGHT and paralyzed users?
- How long does the Insight battery last? How do I recharge? Can I extend the battery life?
- What Is The Emotiv Insight Extender?
- Bluetooth Pairing
- Are CMS/DRL References Positioned As Usually Around The Mastoid?
- Why Does Emotiv EPOC+ Stop At 43 Hz In Range? Is There A Way To Expand This Somehow?
- Measure When The Frequency Ratio Of Alpha To Beta
- What do X-trodes patches provide?
- What are the advantages of X-trodes' Smart Skin?
- How come the electrodes don't require conductive gel?
- Does X-trodes really measure signals from my brain?
- How does X-trodes EEG patches correspond with the 10-20 EEG system?
- Do the X-trodes electrodes come in different sizes?
- Which kinds of signals can I measure with X-trodes electrodes?
- How can I make my skin' Xtrodes electrode patch more flexible?
- How many types of Smart Skin electrodes exist?
- Can I adjust the electrodes to different body areas?
- How long do X-trodes electrodes last?
- Does the location of the ground matter? Can I choose the location?
- Have X-trodes done clinical trials?
- Are the electrodes suitable for all skin types?
- Are the electrodes suitable for children?
- Can signals be obtained from people of varying body weights?
- What type of battery is used in the X-trodes recording system?
- Is the extracted data raw or filtered?
- What is the sample rate of the Bluetooth streamed signals?
- What is the size and weight of X-trodes equipment
- Does the recording system come in additional colors?
- Can I use the X-trodes electrodes more than once?
- Xtrodes User manual and tutorial videos
- List of publications Xtrodes
- International Shipping: Duties and Taxes Policy
- How to get shipping cost estimation?
- Can my delivery address be different from my billing address?
- How long does it take to process my order?
- How can I track my order?
- Can I pick up my order directly at your warehouse?
- Can I change my shipping address after the order has already been shipped?
- Are there any additional costs that will be due upon receipt of my order?
- What is included in the headset package?
- Can I cancel my order?
- What if my order is shipped to the wrong and/or invalid address?
- Can I cancel my order after it has been placed and paid?
- Why was my PRO license suspended?
- How do I cancel my subscription?
- What happens if I upgrade or downgrade my subscription?
- What is PRO-Lite license and how can I access it?
- What happens when I cancel my PRO subscription?
- What happens after my paid PRO license expires?
- Can I upgrade from PRO-LITE to premium PRO licenses?
- My paid PRO licenses have expired and now I can’t access my recordings. What should I do?
- What is EMOTIV’s Refund Policy?
- I received the product but it’s Dead On Arrival. What do I do?
- Can I return a product for Refund?
- What should I know before returning a product?
- When can I get my refund?
- What’s the warranty for EMOTIV Products?
- Can I cancel my order after it has been placed and paid?
-
General Issues
- How to achieve a longer range with EMOTIV USB Receiver?
- I don’t have a Bluetooth(R) SMART (BTLE) compatible device, what do I do?
- Is there any advantage in using the Emotiv Universal USB receiver?
- Why am I seeing dropouts while using Emotiv USB Receiver with the EMOTIV headsets?
- Tips for getting good contact quality with the EMOTIV Headset
- Why do users connect the EMOTIV EPOC X via the USB receiver or Bluetooth?
- We want to embed ECG and EOG electrodoes/systems with EPOC Flex
- Can I measure Delta waves (0-4Hz) with Emotiv hardware?
- Can EPOC capture Gamma?
- Why does Emotiv EPOC+ stop at 43 Hz in range? Is there a way to expand this somehow?
- How accurate is your detection?
- How did EMOTIV build your Detection Suites?
-
EmotivPRO
- Do you show data from CMS/P3, DRL/P4, DRL2/M1, CMS2/M2 in EmotivPRO software?
- Why does the EEG Quality (EQ) in EmotivPRO flicker?
What is the thumb-bridge troubleshooting test for INSIGHT headset functionality?
The Thumb-Bridge Troubleshooting Test is a procedure used to check the functionality of the Insight headset independent of head shape or fit.
1. Make sure the Insight headset is fully charged.
Do this by plugging the Insight charging cable into the headset, and then connecting the cable into a functional USB port on a computer or use a USB adapter to plug into an electrical wall outlet. (Note: If you use a computer make sure it does not go to sleep – the headset will not charge if the computer goes to sleep or is turned off.)
Let the Insight charge for a full 24 hours. Then move to the next step.
2. Connect the Insight via USB dongle or Bluetooth to a computer or mobile device running an Emotiv application.
Within the given application the Contact Quality map will display the contact quality of each channel corresponding to the Insight’s sensors.
3. Place the thumb of one of your hands over BOTH of the sensors on the Reference Arm. The Reference Arm is the black, flexible extension coming from the bottom, left side of the Insight. Make sure the thumb makes strong contact with both of the sensors, otherwise the test will not work.
4. While holding both of the reference sensors, start to gently squeeze. Now, using the other hand gently squeeze one of the other sensors so that your thumb makes strong contact with the sensor pad.
5. Allow for the headset to adjust and start capturing signal by waiting for 5 to 10 seconds.
6. On the Contact Quality Map, the corresponding channel of the sensor that is being squeezed should change from black to red or yellow, then green. The channel should stabilize and stay green as long as you continue to squeeze that sensor.
7. If needed, repeat this Steps 3 through 6 for each sensor to test for full functionality of all the channels.
* The Thumb-Bridge Test may be used for the T7 sensor/channel (the one touching the left temple). This sensor can’t really be squeezed, so instead simply place your thumb on the sensor while applying gentle pressure. The corresponding channel should change to green as described above.
If a certain channel/sensor is problematic and the Thumb-Bridge Test does not get it to turn green then remove the problematic sensor tip and replace it with another one that is functional. Proceed to run the test as described above. If the channel works after the sensor tip is swapped, then the problem is not in the headset itself but with that sensor tip in particular. Conversely, if the after replacing the sensor and the channel remains black on the Contact Quality Map then the problem is within the headset itself and not with the sensor(s).
Updated on 25 Mar 2024
What are your Feelings?
Thanks for your feedback.
Your cart is currently empty.
Start Shopping-
EmotivPRO Student (Monthly) $29.00 /
-
EmotivBCI $0.00 /
-
EPOC X - 14 Channel Wireless EEG Headset $999.00 /